| Sign In | Join Free | My spintoband.com |
|
All variable frequency ct pt analyzer wholesalers & variable frequency ct pt analyzer manufacturers come from members. We doesn't provide variable frequency ct pt analyzer products or service, please contact them directly and verify their companies info carefully.
| Total 304 products from variable frequency ct pt analyzer Manufactures & Suppliers |
|
|
|
Brand Name:HNMC Model Number:FY series Place of Origin:China ...CT PT burden box collection FY47 CT Burden Technical Parameters T Rated Current: 1A Power Factor and Rated Burden: COSΦ=0.8:0.625,1.25,2.5,3.75,5,6.25,7.5,10,12.5,15,20,25,30,40,50,60VA COSΦ=1.0: 0.625,1.25,2.5,3.75,5VA Accuracy Class: ±3% Operation Range: (1%-120%). In Test Cable Resistance: 0.06Ω Frequency: 50Hz or 60HZ Operation Model: By Manual Withstand Voltage: 2kV/1min Insulation: Air FY49 CT... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Brand Name:HNMC Model Number:FY series Place of Origin:China ...CT PT burden box collection FY47 CT Burden Technical Parameters T Rated Current: 1A Power Factor and Rated Burden: COSΦ=0.8:0.625,1.25,2.5,3.75,5,6.25,7.5,10,12.5,15,20,25,30,40,50,60VA COSΦ=1.0: 0.625,1.25,2.5,3.75,5VA Accuracy Class: ±3% Operation Range: (1%-120%). In Test Cable Resistance: 0.06Ω Frequency: 50Hz or 60HZ Operation Model: By Manual Withstand Voltage: 2kV/1min Insulation: Air FY49 CT... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Brand Name:HNMC Model Number:MCCT2000 Place of Origin:China Current Transformer Tester and Analyzer MCCT2000 Specifications Output Voltage Output 0~100V (AC) Current Output 0~15A (Peak) Measurement Current Measurement Accuracy ±0.1% Voltage Measurement Accuracy ±0.1% Secondary Side Voltage Measurement Input 0 ... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Brand Name:HNMC Model Number:MCCT2000 Place of Origin:China Current Transformer Tester and Analyzer MCCT2000 Specifications Output Voltage Output 0~100V (AC) Current Output 0~15A (Peak) Measurement Current Measurement Accuracy ±0.1% Voltage Measurement Accuracy ±0.1% Secondary Side Voltage Measurement Input 0 ... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Brand Name:Emerson Model Number:SP1405 Place of Origin:China ...Variable Frequency Inverter Emerson CT Inverter SP1404 Unidrive SP Description The Inverter SP1405 is a 3kW, 7.6A, 380...480V AC variable frequency drive from the Unidrive SP range manufactured by Control Techniques. As an official Control Techniques distributor, Northern Industrial supply the whole range of Unidrive SP variable frequency... |
Shenzhen Wisdomlong Technology CO.,LTD
Guangdong |
|
|
Brand Name:United electrical Model Number:HZBP-BD Place of Origin:Wuhan, China ...Variable Frequency AC Resonant High Voltage Insulation Tester Product Description: HZBP-BD series variable frequency resonant device is a common primary electrical equipment of substations. It is applied for voltage withstand test of capacitive equipment, such as transformer, GIS system, SF6 switch, CT/PT... |
Wuhan HeZhong Electric Equipment Manufacture Co.,Ltd
Hubei |
|
|
Brand Name:HNMC Model Number:FY61A Place of Origin:China Intelligent Type Current Transformer Burden Box CT Burden FY61A Technical Parameter Rated Current 5A, 1A Operating Range 1-120% Rated Impedance (Ω) COSφ= 0.8 0.1;0.15;0.2;0.3;0.4;;0.6;1.0;1.2; 1.6; 2.4; 3.2 COSφ= 1.0 0.1;0.15;0.2;0.3;0.4 Rated Frequency 50... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Brand Name:HNMC Model Number:FY61A Place of Origin:China Intelligent Type Current Transformer Burden Box CT Burden FY61A Technical Parameter Rated Current 5A, 1A Operating Range 1-120% Rated Impedance (Ω) COSφ= 0.8 0.1;0.15;0.2;0.3;0.4;;0.6;1.0;1.2; 1.6; 2.4; 3.2 COSφ= 1.0 0.1;0.15;0.2;0.3;0.4 Rated Frequency 50... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Brand Name:HNMC Model Number:FL2 Place of Origin:China Intelligent Type Current Transformer Burden Box CT Burden FL2 series Working as secondary load during current transformer testing Full automatic Can provide communication protocol Technical Parameter Rated Current 5A, 1A Working Current Range 1-120% or up ... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Brand Name:HNMC Model Number:FL2 Place of Origin:China Intelligent Type Current Transformer Burden Box CT Burden FL2 series Working as secondary load during current transformer testing Full automatic Can provide communication protocol Technical Parameter Rated Current 5A, 1A Working Current Range 1-120% or up ... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Brand Name:HNMC Model Number:FY96 Place of Origin:China Intelligent Type Potential Transformer Burden Box VT Burden FY96 Technical Parameter Rated Current 100V, 100/√3, 110V, 110/√3more (option) Operating Range 1-200% Rated load (VA) COSφ= 0.8: 1.25-158.75 Rated Frequency 50 or 60HZ Basic Error Active (±3%·g(ms... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Brand Name:HNMC Model Number:MCVT01 Place of Origin:China Portable Capacitance PT Test Equipment MCVT01 Technical Index Accuracy class 0.02 Primary voltage range 35/√3 – 500/√3 kV Secondary voltage 100/√3, 100, 100/3 V Secondary burden range 2.5 – 300VA Power factor 0.8, 1 Rated frequency 50 or 60Hz Power ... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Brand Name:HNMC Model Number:FY96 Place of Origin:China Intelligent Type Potential Transformer Burden Box VT Burden FY96 Technical Parameter Rated Current 100V, 100/√3, 110V, 110/√3more (option) Operating Range 1-200% Rated load (VA) COSφ= 0.8: 1.25-158.75 Rated Frequency 50 or 60HZ Basic Error Active (±3%·g(ms... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Brand Name:HNMC Model Number:MCVT01 Place of Origin:China Portable Capacitance PT Test Equipment MCVT01 Technical Index Accuracy class 0.02 Primary voltage range 35/√3 – 500/√3 kV Secondary voltage 100/√3, 100, 100/3 V Secondary burden range 2.5 – 300VA Power factor 0.8, 1 Rated frequency 50 or 60Hz Power ... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Place of Origin:China Brand Name:Sansion ... level of various insulation materials, insulation structure and electrical produ cts. It is also considered as PD power frequency source for transformers, CT/PTs, HV circuit bre akers, coupling capacitors, bushings and other power equipment. Function: 1. |
Sansion Power Electric Co., Ltd.
Hubei |
|
|
Brand Name:HAOMAI Model Number:CTP-120PA Place of Origin:China CT & VT Analyzer with Multi-tap Switch Box Model: CTP-120PA The CT & VT Analyzer CTP-120PA is a lightweight and portable unit capable of testing both current transformers and voltage transformers. At less than 9kg(19.84 lbs) the CTP-120PA is a highly ... |
HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD
|
|
|
Brand Name:HAOMAI Model Number:CTP-120PA Place of Origin:China CT & VT Analyzer with Multi-tap Switch Box Model: CTP-120PA The CT & VT Analyzer CTP-120PA is a lightweight and portable unit capable of testing both current transformers and voltage transformers. At less than 9kg(19.84 lbs) the CTP-120PA is a highly ... |
HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD
|
|
|
Brand Name:Delta Model Number:VFD007E43T Place of Origin:Taiwan Delta Motor Driver Inverter VFD007E43T or VFDOO7E43T VFD007E43T Product Description Brand Name: Delta Products Model Number: VFD007E43T Alternate Part Number: VFD007E43T Item Category: Drives Series: VFD-E Nominal Input VAC: 480 Volts AC Input Range VAC: ... |
Guangzhou Sande Electric Co.,Ltd.
Hebei |