Brand Name:Infinity Machine Model Number:RS-1000-DA Place of Origin:Made in China ...Test Chamber, Large Three-integrated Test Chamber Model: RS-1000-DA Purpose: This equipment applies to environmental simulation reliability tests such as high and low temperature constant and gradual, abrupt, damp heat test of all kinds of electrical and electronic products and other products, parts and materials. Test standard: ● GB/T2423.1-2008 (IEC60068-2-1:2007) Low temperature test method... |
Infinity Machine International Inc.
Guangdong |
|
|
Brand Name:Infinity Machine Model Number:ID6001 Place of Origin:Made In China ...Testing Machine Model Number:ID6001 Application of equipment: It is suitable for product packaging boxes to simulate the slope impact test caused by the package tilting and sliding during transportation or dock handling to test the reliability of the packaging. Testing standard: =ASTM D880 Standard Test Method for Impact Testing... |
Infinity Machine International Inc.
Guangdong |
|
|
Model Number:009-0029739, 0090029739 Brand Name:NCR Place of Origin:China ...Validator The 009-0029739 / 0090029739 NCR BRM HVD-300U Bill Validator is a key component used in NCR SelfServ 6683 and 6687 ATM machines. This bill validator ensures accurate note acceptance, fast processing, and stable performance in ATM cash handling operations. It is widely used in ATM maintenance, repair, and refurbishment projects. Each unit is carefully tested... |
Tiger Spare Parts Co., Ltd
|
|
|
Brand Name:WINTEAM Model Number:YT Place of Origin:CHINA vhp sterilization dispensing isolator positive pressure isolator Single side Parameter Model size of machine Size of operation Air lock chamber size description YT-R1500 1500*750*2100 1500*650*800 NO Single-sided hard cabin turbulence isolator 3 gloves YT-... |
Hangzhou Winteam Scientific Instruments Co., Ltd.
|
|
|
Brand Name:AI Model Number:SCT-I Place of Origin:China ...Content Tester Lamp Method Summary The sulphur content tester is designed and made as per the national standard of People's Republic of China GB/T380 Standard Test Method for Sulfur Content in Petroleum Products (Lamp Method). It is used to determine the ... |
Advanced Instruments Co.,Limited
Hunan |
|
|
Brand Name:AI Model Number:WTM Place of Origin:China ...-2011 “Bituminous Mixtures Sample Making Method (Wheel-grind Method)” in the Industry Standard of People’s Republic of China JTG E20-2011 Standard Test Methods for Bitumen and Bituminous Mixtures for Highway Engineering. It is suitable to mill ... |
Advanced Instruments Co.,Limited
Hunan |
|
|
Brand Name:Advanced Instruments Model Number:AIC-30011 Place of Origin:China ...Method) is designed and manufactured according to the requirements specified in the industry standard SH/T 0170 of the People's Republic of China, "Determination of Carbon Residue in Petroleum Products (Electric Furnace Method)". It is suitable for determining the carbon residue of lubricating oils, heavy liquid fuels, or other petroleum products using the test method |
Advanced Instruments Co.,Limited
Hunan |
|
|
Brand Name:Advanced Instruments Model Number:AIC-0193 Place of Origin:China ... of oxidation stability-Rotating pressure vessel method and ASTM D2272 Standard test Method for Oxidation Stability of Steam Turbine Oils by Rotating Pressure Vessel. The Automatic Lubricating Oil Oxidation Stability Tester is used to ... |
Advanced Instruments Co.,Limited
Hunan |
|
|
Brand Name:Advanced Instruments Model Number:AIC-0059B Place of Origin:China ... test method for evaporation loss of lubricating oils by the Noack B method.It's suitable to determine lubricating oil. Product Advantages 1. Intelligent Interactive Interface 1).Equipped with a 7-inch full-color high-... |
Advanced Instruments Co.,Limited
Hunan |
|
|
Versatile BMS Testing Apparatus For Thorough Analysis And Validation Of Battery Management FunctionsBrand Name:XWELL Model Number:MD-ADW Place of Origin:China BMS Testing Machine Adjust Telescopic Arm Welding Head Automatic Pulse Welding Product Description The BMS Testing Machine is a crucial tool for ensuring the proper functioning and reliability of Battery Management Systems (BMS). This advanced testing ... |
Guangdong XWELL New Energy Technology CO., LTD.
|
|
|
Brand Name:GDZX Model Number:ZXZL2000 Place of Origin:CHINA ... transformer insulating oil breakdown voltage test equipment The instrument is designed and made as per the National Standard “Test Methods for Interfacial Tension of Oil against Water by the Ring Method”. It is suitable for measuring surface tension (... |
Wuhan GDZX Power Equipment Co., Ltd
Hubei |
|
|
Brand Name:lixian Model Number:HZ-Building Material Fire Tester-14 Place of Origin:CHINA ... propagation rate of exposed surfaces such as walls and ceilings (including solid plastics), at the same time measure smoke density. This test method applies to the exposed surface which includes ceiling or walls, provided that the materials or the whole |
Dongguan Lixian Instrument Scientific Co.,LTD
Guangdong |
|
|
Brand Name:Sinuo Model Number:SN2307 Place of Origin:China ...Test Apparatus For Cables ≤Ø 12.5mm IEC60811-1-4 Clause 8.1 And 8.2 Product description: This device is intended in general for cables with an overall diameter up to and including 12.5 mm, or for flat cables, a major axis dimension up to and including 20 mm. According to the standard IEC60811-1-4 clause 8.1 and 8.2, common test methods for insulating and sheathing materials of electric and optical cables-part 1-4: Methods... |
Sinuo Testing Equipment Co. , Limited
Guangdong |
|
|
Brand Name:HNMC Place of Origin:China ...) Accuracy 0.05% (10mA-12A) 0.2% (clamp-on CT mode) 1% (rogowski coil mode) Resolution High resolution, Six digits valid value Voltage Testing Range 1-576V, maximum can be |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Brand Name:HNMC Place of Origin:China ...) Accuracy 0.05% (10mA-12A) 0.2% (clamp-on CT mode) 1% (rogowski coil mode) Resolution High resolution, Six digits valid value Voltage Testing Range 1-576V, maximum can be |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Brand Name:HongCe Place of Origin:China ... made of rubber and plastic. Test method: The test piece is immersed in hot oil for a period of time and then the test piece is taken out to test the tensile strength. Technical Parameters Quartz tube: ф38mm, depth 250mm; Oil tank size: 350 × 350 × |
Guangzhou HongCe Equipment Co., Ltd.
Guangdong |
|
|
Brand Name:HongCe Model Number:CXT2510 Place of Origin:China ...Testing Equipment Conductor Resistance Meter Basic Accuracy 0.02% Product description: This resistance tester is a high-precision tester specially designed and developed for ultra-low DC resistance test. The measuring range of the instrument is: 0.01u Ω ~ 10m Ω; The display digit is five and a half digits; Automatic bidirectional current test, pulse test method avoids the heat generated by the test circuit and affects the test |
Guangzhou HongCe Equipment Co., Ltd.
Guangdong |
|
|
Brand Name:HongCe Model Number:CXT2510 Place of Origin:China .... The measuring range of this instrument is: 0.01uΩ~10MΩ; The display bits are five and a half; Automatic bidirectional current test, pulse test method to avoid the test loop heat affect the test accuracy, the test cable resistivity without a variety of |
Guangzhou HongCe Equipment Co., Ltd.
Guangdong |
|
|
Brand Name:HongCe Model Number:HJ124 Place of Origin:China ... extremely low leaks, also for big volumes of the part and in any environmental condition. The possibility to identify the origin of the leak on parts that have been previously detected as scrap in a global testing, makes the |
Guangzhou HongCe Equipment Co., Ltd.
Guangdong |
|
|
Brand Name:Medpharm Model Number:SQ-HV Place of Origin:China ... the chamber environment to meet the ideal conditions for temperature, pressure and humidity. First air is removed from the chamber to allow for gas penetration. A leakage test is performed, to ensure that staff and |
ZHANGJIAGANG MEDPHARM MACHINERY LTD.
Jiangsu |