| Sign In | Join Free | My spintoband.com |
|
All overload sensor wholesalers & overload sensor manufacturers come from members. We doesn't provide overload sensor products or service, please contact them directly and verify their companies info carefully.
| Total 1886 products from overload sensor Manufactures & Suppliers |
|
|
|
Brand Name:CITY Model Number:4OX-V SR-X2V AAY80-390 Place of Origin:UK .... O2 Maximum Overload 30% vol. O2 Output Signal 0.10 ± 0.02 mA in Air Response Time (T90) <15 Seconds Zero ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:YJJ Model Number:XGZP6161D Place of Origin:CHINA ...Sensor Transmitter Remote Pressure Gauge Water Meter Pump Wireless Transmission Air Pressure Internet Pf Things 1MPa 2.5MPa Features: Product Features · Measurement range: 0-1MPa... 2.5 MPa · Ceramic flat membrane structure Compact structure and high reliability Advanced anti-interference and insulation properties · Resistant to impact, overload... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:Original Factory Model Number:IM69D120V01 Place of Origin:CN ...Sensor IC High Performance Digital XENSIV MEMS Microphone PG-LLGA-5-1 Product Description Of IM69D120V01 IM69D120V01 is High performance digital XENSIV MEMS microphone. IM69D120V01 is designed for applications where low self-noise (high SNR), wide dynamic range, low distortions and a high acoustic overload... |
ShenZhen Mingjiada Electronics Co.,Ltd.
|
|
|
Model Number:H2/CA-1000 Place of Origin:Switzerland ... Gas Sensor For Medical Applications Key Features : Highly selective H2 detection in presence of CO Applications: • Medical Applications • H2 Detection in H2/CO-Mixtures • Medical Applications Nominal Range 0 - 1000 ppm Maximum Overload 2000 ppm... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:H2-1000 Place of Origin:CN ...Sensor Is Mainly Used To Detect Hydrogen Gas Product Features: High Sensitivity and Resolution: Capable of detecting low-concentration hydrogen gas, with resolutions as low as 0.1 ppm (depending on the specific model), ensuring accurate monitoring even at trace levels. Wide Measurement Range: Typically covers 0 - 1000 ppm, with a maximum overload... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:YJJ Model Number:4HS-LM AC226-800 Place of Origin:USA ...4HS/LM AC226-800 0-100 ppm Electrochemical Hydrogen Sulfide Gas Sensor Is Used For H2S Concentration Detection Features: Performance Characteristics Nominal Range:0-100 ppm Maximum Overload:500 ppm Expected Operating Life:Two years in air Output Signal:0.... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:S22P015S05M2 Place of Origin:Japan ...motor, helping to monitor the operating status of the motor, detect overloads, under - currents and other abnormal conditions, and ensure the safe and efficient operation of the motor. Power Supply Monitoring: Applied in switch - mode power ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:4OX-V-CN 4OXV-CN AAY80-390-CN Place of Origin:CN .... Applications: General purpose, portable or fixed life safety. Measurement Technology Electrochemical Measurement Range 1 - 25% vol. O₂ Maximum Overload 30% vol. O₂ Output Signal 0.10 ± 0.02 mA in air Response Time (T90) < |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:YJJ Model Number:NO/C-1 Place of Origin:Switzerland ... Maximum Overload 2 ppm Inboard Filter - Output Signal 3000 ± 1200 nA/ppm Resolution (Electronics dependent) < 0.01 ppm T90 ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:Yunyi Model Number:3051 Place of Origin:China ... circuits to improve measurement accuracy. Adopting a standardized installation structure design, it is easy to install and use. The sensitive membrane has one-way overload protection capability, with a |
Xi'an Yunyi Instrument Co., Ltd
|
|
|
Model Number:3SO2-2000CT Place of Origin:CN 3SO2-2000CT 3‑Electrode Electrochemical SO₂ Sensor For Stack Emission Monitoring Harsh‑Environment Gas Analysis Key Features: Measurement Principle: 3‑electrode electrochemical Range: 0–2000 ppm SO₂; Max Overload: 5000 ppm Sensitivity: 0.10 ± ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:4CO-AF Place of Origin:CHINA Brand Name:YJJ ... Triple-electrode electrochemistry Unbiased voltage, current-type output Range 0~100 ppm (standard) Extended: 0~200 ppm Overload ≤ 2000 ppm No |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Place of Origin:USA Brand Name:YJJ Model Number:FMAMSDXX015WC2C3 ... Type Micro Force Sensor 15N (1.53kgf) Features: 1. Key Parameters (Standard Version) Table Parameters Values Remarks Model FMAMSDXX015WC2C3 MicroForce FMA series Range 0 - 15N (1.53kgf) Compression force measurement, overload protection 3× range Output ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Place of Origin:CHINA Brand Name:YJJ Model Number:4LEL-3.0V 090-R000-000 Product Description: YJJ 4LEL-3.0V 090-R000-000 Catalytic Combustion Flammable Gas LEL Sensor Features: I. Core Parameters (Quick Overview) Range: 0–100% LEL (Lower Explosive Limit) Maximum Overload: 100% LEL Sensitivity (20℃, CH₄): 22±7 mV/%CH₄ Response ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:4H2S-2000 052-0600-000 Place of Origin:CHINA Brand Name:YJJ ... Gas: Hydrogen Sulfide (H₂S) Range: 0–2000 ppm Maximum Overload: 4000 ppm (short-term withstandable) Sensitivity: 0.09 ± 0.04 μA/ppm T90 Response Time: ≤ 45 s Baseline (Zero ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:4NH3-100 059-0000-000 Place of Origin:CHINA Brand Name:YJJ ...0600-000 Electrochemical Hydrogen Sulfide Sensor 0-2000 ppm for Portable/Fixed Detectors Features: I. Core Parameters (20℃, 50% RH) 1. Measurement Performance Measurement Gas: Ammonia (NH₃) Range: 0–100 ppm Maximum Overload: 200 ppm (short-term) ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Place of Origin:CHINA Model Number:3CO-4000CT 051‑3400‑100 Brand Name:YJJ ... 0-4000PPM Electrochemical Carbon Monoxide (CO) Sensor for Flue Gas / Boiler Emissions Features: I. Core Parameters (20℃, standard atmospheric pressure) 1. Detection Performance Range: 0–4000 ppm CO Maximum Overload: 20000 ppm (short-term) Sensitivity... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Place of Origin:UK Model Number:CL2-A1 ... 0–20 ppm Maximum Overload Concentration 35 ppm Sensitivity (@10ppm Cl2) -350 ~ -750 nA/ppm Resolution 20 ppb (ultra-high ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:MPXV5010DP Brand Name:YJJ Place of Origin:USA ... Pressure Sensor HVAC and Medical Applications Features: I. Core Parameters 1. Pressure Range Measurement Type: Differential Pressure (Differential), Dual Inlet P1-P2 Range: 0 - 10 kPa (0 - 1.45 PSI, approximately 1000mm water column) Maximum Overload: 40 ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:HSDP-A1000U HSDP-A1000UL Brand Name:YJJ Place of Origin:USA ...-A1000UL (UL = with 5-digit LCD local digital display) Measurement Range: ±1000Pa (-1000 ~ +1000Pa air pressure difference) Overload Resistance Pressure: 10kPa (10 times full scale, resistant to |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |