Brand Name:Membrapor Model Number:CO/CF-1000 Place of Origin:Switzerland ... 0 - 1000 ppm Maximum Overload 2000 ppm Inboard Filter To remove acidic gases Output Signal 100 ± 20 nA/ppm Resolution (Electronics ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:SGX Sensortech Model Number:SGX-4NO2 Place of Origin:UK ...Dioxide NO2 Gas Air Quality Sensors PERFORMANCE Output signal 600 ± 150 nA / ppm Typical Baseline Range (pure air) ±0.2ppm NO2 equivalent T90 Response Time < 30 seconds Measurement Range 0 - 30 ppm Maximum Overload 200 ppm Repeatability <±2% NO2 ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:CITY Model Number:4H AC200-800 Place of Origin:USA 4H AC200-800 Hydrogen Sulfide H2S Gas Sensor Low Detection For Industrial Applications Specification: Operating Principle 3-electrode electrochemical Measurement Range 0-100 ppm Maximum Overload 500 ppm Resolution 0.1PPM Filte None Sensitivity 1.20 ± 0.25... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:YJJ Model Number:4OL CLE-0231-400 Place of Origin:USA 4OL CLE-0231-400 Oxygen Gas Sensors 0-30% Vol New Style Performance Characteristics Part Number CLE-0231-400 Nominal Range 0 to 30% O2 Maximum Overload 90% O2 Output Signal -350 ± 50 μA in air Zero Signal -40 ~ 10 μA in Nitrogen Resolution 0.1% O2 ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:SUSA Model Number:4O2-GP (P/N 114-230-350) Place of Origin:Britain ... Zero drift (-20 to 40°C) of 0.6% Response time < 15 s Repeatability < 2% signal value/monthly line Linearity of sex Specifications: Overload 30% O2 Resolution <15s Linear error < 1 |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:CITY Model Number:3EF 3E/ F AB004-J08 Place of Origin:Britain Product Description: Three-electrode CO Gas Sensor 3EF 3E/ F AB004-J08 Features: Nominal Range :0-1000ppm Maximum Overload:2000ppm Expected Operating Life:Three years in air Output Signal:0.10 ± 0.02 µA/ppm Inboard Filter (3E/F only):To remove ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:CITY Model Number:3HHLM AC005-J00 Place of Origin:Britain ...3HHLM AC005-J00 Three-electrode Electrochemical Hydrogen Sulfide (H2S) Gas Sensor Features: MEASUREMENT Operating Principle:3-electrode electrochemical Measurement Range:0-50 ppm H2S Maximum Overload:500 ppm H2S Filter:None Sensitivity:1.70 ± 0.30 μA/ppm... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:CITY Model Number:3HYE AE006-J30 Place of Origin:Britain Product Description: 3HYE AE006-J30 3 Series Electrochemical Gas Hydrogen H2 Sensor For Hydrogen Detector H2 Concentration Tester Features: Nominal Range:0-10 000ppm Maximum Overload:20 000ppm Expected Operating Life:Two years in air Output Signal:0.003... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:CITY Model Number:3ST/F AD004-J04 Place of Origin:Britain Product Description: 3ST/F AD004-J04 0-100PPM3 Series Sulfur Dioxide (SO2) Sensor Features: Nominal Range 0-100ppm Maximum Overload 500ppm Inboard Filter To remove H2S Expected Operating Life Two years in air Output Signal 0.37 ± 0.07 µA/ppm ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:CITY Model Number:4CFC 2112B2006 Place of Origin:Britain Product Description: 4CFC Carbon Monoxide (CO) Gas Sensor Part Number: 2112B2006 Features: Nominal Range 0-1000 ppm CO Maximum Overload 2000 ppm CO Inboard Filter To remove H2S Expected Operating Life Two years in air Output Signal 0.37 ± 0.07 µA/... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:NEMOTO Model Number:NE-CO-BL NE4-CO-BL Place of Origin:Japan ...Sensors Have Long Life And Low Power Consumption Features: Good responsiveness and high output current. Handle complex gases with ease. Excellent linearity. Long life and good stability. Durable in complex environments. Detection gas: CO General range :0~ 1,000ppm Overload... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:DDS Model Number:GS+4COF-M Place of Origin:Britain ...High-performance Electrochemical Carbon Monoxide Sensor For Gas Detectors Features: Output signal: 15 ± 5 nA/ppm Typical baseline range: <±10 ppm CO equivalent T90 Response time: < 30 seconds Range: 0-40,000 ppm Maximum overload: 10,000 ppm < 30 seconds ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:CITY Model Number:4OX-V SR-X2V AAY80-390 Place of Origin:UK .... O2 Maximum Overload 30% vol. O2 Output Signal 0.10 ± 0.02 mA in Air Response Time (T90) <15 Seconds Zero ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:H2/CA-1000 Place of Origin:Switzerland ... Gas Sensor For Medical Applications Key Features : Highly selective H2 detection in presence of CO Applications: • Medical Applications • H2 Detection in H2/CO-Mixtures • Medical Applications Nominal Range 0 - 1000 ppm Maximum Overload 2000 ppm... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:H2-1000 Place of Origin:CN ...Sensor Is Mainly Used To Detect Hydrogen Gas Product Features: High Sensitivity and Resolution: Capable of detecting low-concentration hydrogen gas, with resolutions as low as 0.1 ppm (depending on the specific model), ensuring accurate monitoring even at trace levels. Wide Measurement Range: Typically covers 0 - 1000 ppm, with a maximum overload... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:YJJ Model Number:4HS/LM AC226-800 Place of Origin:USA ...4HS/LM AC226-800 0-100 ppm Electrochemical Hydrogen Sulfide Gas Sensor Is Used For H2S Concentration Detection Features: Performance Characteristics Nominal Range:0-100 ppm Maximum Overload:500 ppm Expected Operating Life:Two years in air Output Signal:0.... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:S22P015S05M2 Place of Origin:Japan ...motor, helping to monitor the operating status of the motor, detect overloads, under - currents and other abnormal conditions, and ensure the safe and efficient operation of the motor. Power Supply Monitoring: Applied in switch - mode power ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:4OX-V-CN 4OXV-CN AAY80-390-CN Place of Origin:CN .... Applications: General purpose, portable or fixed life safety. Measurement Technology Electrochemical Measurement Range 1 - 25% vol. O₂ Maximum Overload 30% vol. O₂ Output Signal 0.10 ± 0.02 mA in air Response Time (T90) < |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Brand Name:YJJ Model Number:NO/C-1 Place of Origin:Switzerland ... Maximum Overload 2 ppm Inboard Filter - Output Signal 3000 ± 1200 nA/ppm Resolution (Electronics dependent) < 0.01 ppm T90 ... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
|
|
Model Number:3SO2-2000CT Place of Origin:CN 3SO2-2000CT 3‑Electrode Electrochemical SO₂ Sensor For Stack Emission Monitoring Harsh‑Environment Gas Analysis Key Features: Measurement Principle: 3‑electrode electrochemical Range: 0–2000 ppm SO₂; Max Overload: 5000 ppm Sensitivity: 0.10 ± ... |