| Sign In | Join Free | My spintoband.com |
|
All average cpu temp wholesalers & average cpu temp manufacturers come from members. We doesn't provide average cpu temp products or service, please contact them directly and verify their companies info carefully.
| Total 585 products from average cpu temp Manufactures & Suppliers |
|
|
|
Brand Name:Meeting Model Number:MD30D Place of Origin:Guangzhou China ... 3 . Rated Cooling capacity : 7KW 4 . Hot water supply : 260L / h 5 . Average heating input power : 3KW 6 . Rated heating input current : 13 / 6A 7 . Max outlet water temp : 6 ℃ 8 . COP : 4 9 . Power : 220V/380/50V/Hz 10 . Noise 54Db ( a ) 11 . Dimension |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MDN50D Place of Origin:Guangzhou China ... 2 Hot water supply : 380L / h 3 Average heating input power :4KW 4 Rated heating input current : 9A 5 Max outlet water temp : 60℃ 6 COP : 4.2 7 Power : 380V/50HZ 8 Noise : 48Dba ( a ) 9 Dimension W*D*H : 1200*700*1360mm 10 packing size W*D*H : |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MDY40D Place of Origin:Guangzhou China ... capacity 10 4 . Hot water supply 360L / h 5 . Average heating input power 4 KW 6 . Rated heating input current 9A 7 . Rate outlet water temp 80℃ 8 . COP 4.2 9 . Refrigerant R417A /R410/R407C 10 . Noise 55Db ( a ) 11 . Air source heat exchanger Finned ... |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MD30D Place of Origin:Guangzhou China ... capacity 7 4 . Hot water supply 260L / h 5 . Average heating input power 3 KW 6 . Rated heating input current 9A 7 . Rate outlet water temp 80℃ 8 . COP 4 9 . Refrigerant R417A 10 . Noise 54Db ( a ) 11 . Air source heat exchanger Finned heat exchange ... |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MD50D Place of Origin:Guangzhou China ... water temp 80℃ 8 . COP 4.2 9 . Refrigerant R417A 10 . Noise 55Db ( a ) 11 . Air source heat exchanger Finned heat exchange ... |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MD200D Place of Origin:Guangzhou China ... 7 . Rate outlet water temp 80℃ 8 . COP 4.2 9 . Refrigerant R417A 10 . Noise 65Db ( a ) 11 . Air source heat exchanger Finned heat exchange ... |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MD60D Place of Origin:Guangzhou China ...capacity 21KW 3 . Rated Cooling capacity 15 4 . Hot water supply 520L / h 5 . Average heating input power 5.68 KW 6 . Rated heating input current 12A 7 . Rate outlet water temp 80℃ 8 . COP 4.2 9 . Refrigerant R417A 10 . Noise 60Db ( a ) 11 . Air source... |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MDN50D Place of Origin:Guangzhou China ... heating capacity : 16KW 2 Hot water supply : 380L / h 3 Average heating input power :4KW 4 Rated heating input current : 9A 5 Max outlet water temp : 60℃ 6 COP : 4.2 7 Power : 380V/50HZ 8 Noise : 48Dba ( a ) 9 Dimension W*D*H : 1200*700*1360mm 10 packing size W*D... |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MD50D Place of Origin:Guangzhou China ... capacity KW 18 Rated Cooling capacity 12 Hot water supply L/h 400 Average heating input power KW 4.4 Rated heating input current A 9 Max outlet water temp C 60 COP 4.2 Power V/Hz 380V/50 Noise Db(a) 55 Dimension W*D*H mm 1120*490*1270 Packing ... |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MD50D Place of Origin:Guangzhou China ... capacity KW 18 Rated Cooling capacity 12 Hot water supply L/h 400 Average heating input power KW 4.4 Rated heating input current A 9 Max outlet water temp C 60 COP 4.2 Power V/Hz 380V/50 Noise Db(a) 55 Dimension W*D*H mm 1120*490*1270 Packing ... |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MD30D Place of Origin:Guangzhou China ...heating capacity KW 12 Rated Cooling capacity 7 Hot water supply L/h 260 Average heating input power KW 3 Rated heating input current A 13/6 Max outlet water temp ℃ 60 COP 4 Power V/Hz 220V/380/50 Noise Db(a) 54 Dimension W*D*H mm 1120*490*710mm ... |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MD30D Place of Origin:Guangzhou China ... Rated heating capacity KW 12 Rated Cooling capacity 7 Hot water supply L/h 260 Average heating input power KW 3 Rated heating input current A 13/6 Max outlet water temp ℃ 60 COP 4 Power V/Hz 220V/380/50 Noise Db(a) 54 Dimension W*D*H mm 1120*490*710mm ... |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MD60D Place of Origin:Guangzhou China ... capacity : 15KW 3. Hot water supply : 520L / h 4. Average heating input power : 5.68KW 5. Rated heating input current : 12A 6. Max outlet water temp : 60 ℃ 7. COP : 4.2 8. Power : 380/50V / Hz 9. Noise :60 Db(a) 10. Dimension W*D*H :1120*490*1270mm 11. ... |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MDY150D Place of Origin:Guangzhou China ... Specification MODEL Unit MDY150D Rated heating capacity KW 50 Rated Cooling capacity KW 37 Average input power KW 11 Rated input current A 24 Max outlet water temp C 38 COP 4.5 Power V/Hz 380V/50 Noise Db(a) 60 Dimension W*D*H mm 1450×760×1060 Packing ... |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MDY200D Place of Origin:Guangzhou China ... Technical data sheet MODEL Unit MDY200D Rated heating capacity KW 84 Average heating input power KW 19 Rated heating input current A 35 Max outlet water temp ℃ 35 COP 4.5 Power V/Hz 380V/50 Noise Db(a) 65 Dimension W*D*H mm 1990*980*2080 Packing ... |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MD100D Place of Origin:Guangzhou China ... capacity 36KW 2 Rated Cooling capacity 24KW 3 Hot water supply L/h 800L / h 4 Average heating input power KW 9.2KW 5 Rated heating input current A 18A 6 Max outlet water temp 60℃ 7 COP 4.2 Product Advantage: 1 . Compressor The world - famous Copeland |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MD100D Place of Origin:Guangzhou China ... Quick Details 1. Rated heating capacity : 36KW 2. Rated Cooling capacity : 24KW 3. Hot water supply : 800L / h 4. Average heating input power : 9.2KW 5. Rated heating input current : 18A 6. Max outlet water temp : 60 ℃ 7. COP : 4.2 8. Power : 380/50V / |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MD50D Place of Origin:Guangzhou China ... heating capacity KW 18 Rated Cooling capacity 12 Hot water supply L/h 400 Average heating input power KW 4.4 Rated heating input current A 9 Max outlet water temp C 60 Power V/Hz 380V/50 Noise Db(a) 55 Dimension W*D*H mm 1120*490*1270 Packing size W*D*H ... |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MD60D Place of Origin:Guangzhou China ... 15 4 . Hot water supply 520L / h 5 . Average heating input power 5.68 KW 6 . Rated heating input current 12A 7 . Rate outlet water temp 80℃ 8 . COP 4.2 9 . Refrigerant R417A 10 . Noise 60Db ( a ) 11 . Air source heat exchanger Finned heat exchange ... |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |
|
|
Brand Name:Meeting Model Number:MD100D Place of Origin:Guangzhou China ... water supply : 800L / h 4. Average heating input power : 9.2KW 5. Rated heating input current : 18A 6. Max outlet water temp : 60 ℃ 7. COP : 4.28. Power : 380/50V / Hz 8. Noise :60 Db(a) 10. Dimension W*D*H :1450*760*1060mm 9. |
Guangzhou Jin Lun Electric Equipment Co.,Ltd
Guangdong |