All Worm wholesalers & Worm manufacturers come from members. We doesn't provide Worm products or service, please contact them directly and verify their companies info carefully.
| Total 1002 products from Worm Manufactures & Suppliers |
|
|
|
Model Number:JY-SC4PS-33+ Place of Origin:Shenzhen, Guangdong, China Brand Name:JYRF Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Frequency Range 300-3000 - - - MHz Insertion Loss 300-3000 - 6.4 7.0 dB Isolation 300-3000 20 23 - dB Amplitude Unbalance 300-3000 - 0.2 0.5 dB Phase Unbalance 300-3000 - 2 5 deg ... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Model Number:JY-VLF-2500+ Brand Name:JYRF Place of Origin:Shenzhen, Guangdong, China Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Passband Insertion Loss DC-2500 - 1.0 1.2 dB VSWR DC-2500 - 1.2 1.7 :1 Stop Band Rejection - 25 - - dB Features rugged uni-body construction, small size 7 sections excellent power ... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Place of Origin:Shenzhen, Guangdong, China Brand Name:JYRF Model Number:JY-VHF-650+ Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Stop Band Rejection DC-390 - - 40 dB Stop Band Rejection DC-480 - - 20 dB Cut-off Frequency (3dB) 650 - - 3 dB Passband Insertion Loss 850-2000 - - 1.3 dB Passband Insertion Loss 710-... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Model Number:JY-SBP-21.4+ Place of Origin:Shenzhen, Guangdong, China Brand Name:JYRF Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Center Frequency - - 21.4 - MHz Pass Band 19.2-23.6 - - - MHz Insertion Loss 19.2-23.6 - - 1.5 dB 3 dB Bandwidth 17.9-25.3 - - - MHz Stop Band, Rejection (Loss > 20 dB) 15.5 & 29 20... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Place of Origin:China Model Number:JY-VLFG-1575+ Brand Name:JYRF JY-VLFG-1575+ LTCC Low Pass FilterProduct Overview JY-VLFG-1575+ is a LTCC Low Pass Filter with DC-1575 MHz passband, 50 ohm impedance in a Connectorized package. It offers low insertion loss and high stopband rejection, making it ideal for RF front-end... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Brand Name:JYRF Place of Origin:Shenzhen, Guangdong, China Model Number:JY-BPF-F200+ Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band 195-205 - - - MHz Center Frequency - - 200 - MHz Insertion Loss 195-205 - 7 8 dB VSWR 195-205 - 1.58 1.92 :1 Stop Band, Lower Insertion Loss DC-182 50 60 - dB Stop Band, ... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Brand Name:JYRF Model Number:JY-TA0959A Place of Origin:Shenzhen, Guangdong, China Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Center Frequency (Fc) - - 746 - MHz Insertion Loss 740~752 - 1.8 4.5 dB Amplitude Ripple 740~752 - - 2.0 dB VSWR 740~752 - - 2.2 - Input Power Level - - - 10 dBm Features Low insertion... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Place of Origin:Shenzhen, Guangdong, China Brand Name:JYRF Model Number:JY-TT2.5-6-KK81+ ... (MHz) Min. Typ. Max. Unit Impedance Ratio 0.01-50 - 1:2.5 - - Frequency Range 0.01-50 - - - MHz Insertion Loss 0.01-50 - 1.0 2.0 dB Amplitude Unbalance 0.01-50 - - 0.5 dB Phase Unbalance 0.01-50 - - 5 deg Features RoHS compliant Applications Impedance... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Model Number:TFBP5R64/R4-9SA Brand Name:JYRF Place of Origin:China Electrical Specifications ParameterSpecificationTest Condition Passband (BW 1dB) 5.44-5.84 GHz Insertion Loss ≤ rated Insertion Loss (IL0) ≤3.5 dB @ f0 Rejection (Rfs) ≥40dB@4.7GHz @ f1 Rejection (Rfs) ≥40dB@6.6GHz @ f2 VSWR ≤1.8 In band Size 7.5*6.0*0.26 ... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Model Number:JY-TA0649A Brand Name:JYRF Place of Origin:Shenzhen, Guangdong, China Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Center Frequency (Fc) - - 433.92 - MHz Insertion Loss 433~434.71 - 2.0 2.7 dB Amplitude Ripple 433~434.71 - - 2.0 dB VSWR 433~434.71 - - 2.2 - Input Power Level - - - 10 dBm Features ... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Place of Origin:Shenzhen, Guangdong, China Brand Name:JYRF Model Number:JY-TA0872A Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Center Frequency (Fc) - - 1687.5 - MHz Insertion Loss 1675.5~1699.5 - 3.3 4 dB Amplitude Ripple 1675.5~1699.5 - - 2.0 dB VSWR 1675.5~1699.5 - - 2.2 - Input Power Level - - - 10 dBm ... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Place of Origin:China Brand Name:JYRF Model Number:JY-TTC1-682W+ JY-TTC1-682W+ Balun TransformerProduct Overview JY-TTC1-682W+ is a balun transformer designed for RF and communication systems, offering reliable performance in a compact surface mount package.Electrical Specifications ParameterSpecification Frequency ... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Model Number:JY-ADC-10-4+ Brand Name:JYRF Place of Origin:Shenzhen, Guangdong, China Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Frequency Range 5-1000 - - - MHz Nominal Coupling 5-1000 - 10 - dB Mainline Loss 5-1000 - 0.25 0.5 dB Directivity 5-1000 15 17 - dB Features wideband, 5-1000 MHz low mainline loss, 0.8... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Place of Origin:Shenzhen, Guangdong, China Brand Name:JYRF Model Number:JY-TA0974A Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Center Frequency (Fc) - - 1120 - MHz Insertion Loss Fc±4 (1116~1124) - 2.8 5 dB Amplitude Ripple Fc±4 (1116~1124) - - 2.0 dB VSWR Fc±4 (1116~1124) - - 2.2 - Input Power Level - - - 10 ... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Place of Origin:Shenzhen, Guangdong, China Brand Name:JYRF Model Number:JY-RBDC-20-63+ Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Frequency Range DC-6000 - - - MHz Nominal Coupling DC-6000 - 20 - dB Mainline Loss DC-6000 - 0.25 0.5 dB Directivity DC-6000 15 17 - dB Features Wideband, DC-6000 MHz Low insertion ... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Brand Name:JYRF Place of Origin:China Model Number:JY-HFTC-9R5+ JY-HFTC-9R5+ LTCC High Pass FilterProduct Overview JY-HFTC-9R5+ is a LTCC High Pass Filter with 1300-3500 MHz passband, 50 ohm impedance in a SMT package. It offers low insertion loss and high stopband rejection, making it ideal for RF front-end and ... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Model Number:JY-TT1-6-KK81J+ Brand Name:JYRF Place of Origin:Shenzhen, Guangdong, China Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Impedance Ratio 0.004-300 - 1:1 - - Frequency Range 0.004-300 - - - MHz Insertion Loss 0.004-300 - 1.0 2.0 dB Amplitude Unbalance 0.004-300 - - 0.5 dB Phase Unbalance 0.004-300 - - 5 ... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Brand Name:JYRF Model Number:JY-CBP-1538J+ Place of Origin:Shenzhen, Guangdong, China Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Pass Band 1518-1559 - - - MHz Center Frequency - - 1538 - MHz Insertion Loss 1518-1559 - 1.1 1.7 dB VSWR 1518-1559 - 1.6 2.32 :1 Stop Band, Lower Insertion Loss DC-1390 20 27.4 - dB ... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Place of Origin:Shenzhen, Guangdong, China Model Number:JY-TA0908B Brand Name:JYRF Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Center Frequency (Fc) - - 875 - MHz Insertion Loss 870~880 - 2.8 4.2 dB Amplitude Ripple 870~880 - - 2.0 dB VSWR 870~880 - - 2.2 - Input Power Level - - - 10 dBm Features Low insertion... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |
|
|
Brand Name:JYRF Model Number:JY-SXBP-27R5+ Place of Origin:Shenzhen, Guangdong, China Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Center Frequency - - 27.5 - MHz Pass Band 24-31 - - - MHz Insertion Loss 24-31 - 1.3 2.5 dB VSWR (Passband) 24-31 - 1.4 1.7 :1 Stop Band (Lower), Rejection DC-19 20 30 - dB Stop Band (... |
Jieying Communication Technology (Shenzhen) Co., Ltd.
Guangdong |