ZXCBB Variable Ratio Group Tester Verification Device for Testing the Accuracy & Resolution of Ratio Tester
![]() |
... turn ratio testers with accuracy at 0.5 or below 0.05. It is composed of two parts: standard three phase PT and inductive voltage divider. The PT is used to test ratio group test function of the ratio tester, inductive voltage divider is used to test the...
Wuhan GDZX Power Equipment Co., Ltd
|
Range 0.9~10000 Transformer Testing Equipment Automatic Variable Ratio Grouping Tester
![]() |
...ensure the required voltage transformation. 2. Check whether the indicated position of the voltage tap changer is correct.Transformer ratio tester test can achieve what purpose and results 3. Check the ratio of turns of each coil to determine whether there...
Wuhan Rising Electric Co., Ltd.
|
Ratio and vector group tester
![]() |
...Ratio Meter HYBC-901 2. Equipment Description: HYBC-901 Tansformer ratio meter z type is specially designed for three- phase transformer in power system, especially for transformer of type Z winding and other transformers whose zero-load current is relatively high. The tester......
Wuhan Huaying Electric Power Tech & Science Co.,ltd
|
TTR-I Single Phase and Three Phase Transformer Turns Ratio Tester
![]() |
... can be applied to test the turns ratio and group vector of single or three phase transformer. The connection group of three phase transformer also can be calculated with the ratio. All parameters can be measured in one test for three phase transformer....
Delta Technology (Chongqing) Co., Ltd.
|
Single Phase and Three Phase Transformer Turns Ratio Tester with Printer
![]() |
...Ratio Tester is designed according IEC76-1 and IEC60044. It can be applied to test the turns ratio and group vector of single or three phase transformer. The connection group of three phase transformer also can be calculated with the ratio. All parameters can be measured in one test for three phase transformer. Functions of Transformer Turns Ratio Tester......
Advanced Instruments Co.,Limited
|
Automatic Power Transformer Electrical Test Equipment Group Turns Ratio Tester
![]() |
...Group Turns Ratio Tester With 58mm printer In power transformer Finished product production process, before the new installation of the transformer in operation, according to the national ministry of preventive test procedures, require the operation of transformer turn ratio or voltage ratio test, to check the correctness of the transformer turn ratio......
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
|
0.2 Class Transformer Test Equipment , 10000 Transformer Turn Ratio Tester
![]() |
...Ratio Test Set MCTTR301 Main Features 1) LCD display 2) Measure single phase or three phase transformer turn ratio 3) Auto switch phase sequence and ranges 4) Auto calculate voltage regulation ratio 5) Ratio measurement & Ratio Error calculation by input standard ratio 6) Can test CT ratio and display excitation current 7) Group vector measurement; can auto measure single&three phase transformer group......
Zhengzhou Great Electric Co.,Ltd.
|
Single Electrical Test Set / Three Phase Transformer Turns Ratio Meter TTR Meter
![]() |
... for three phase transformer. The polarity measurement for single phase transformer or CT/PT Voltage ratio error calculation Current transformer ratio measurement Excitation current measurement in ratio testing Reproduction the AC test voltage from...
DONGGUAN YUYANG INSTRUMENT CO., LTD
|
0.9-10000 Transformer Turn Ratio Tester 3-phase XHBB128B
![]() |
...Ratio Tester Description In the production process of semi-finished and finished power transformers, before the newly installed transformer is put into operation and according to the preventive test regulations of the Ministry of Electric Power, it is required to test the turns ratio or voltage ratio of the operating transformer, and the transformer turns ratio......
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
|
999 Second Radiator Leak Tester For Precise Leak Detection 0.1KPa Minimum Detectable Rate
![]() |
...test data to U disk. It is powered by 220AV and has a time setting of 0~999 second with pressure unit of Bar/PSI/KPA. It has 32 groups(0~31) number of parameter channels for air leak tester and air dry radiator tester, and it can be set from 0~999 second....
FOSHAN SUNHOPE CO.,LTD.
|