Packaging Details: carton
Test voltage range: 0-600V
Test current range: 5mA-20A
Power factor: -1.000~1.000
Power freqency: 0.5Hz~ 100KHz
Accuracy: ±0.2%
Input: AC100V ~ 240V, 50Hz/60Hz
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

0.2 Grade Accuracy Digital Power Meter with 0.5Hz to 1000KHz Bandwidth and 5" IPS LCD Display

0.2 Grade Digital Power Meter with Bandwidth 0.5Hz to 1000KHz

1. Introduction

This is a multifunctional digital power meter for measuring the power of single - phase (1P/2W) AC and DC power supplies. The test frequency range of this product can reach DC 0.5Hz - 100kHz. It uses a 5" IPS LCD display screen, has a 5 - digit measurement display, enables simultaneous measurement of multiple parameters, and possesses high - precision measurement capability. At the same time, it has functions such as waveform display (voltage/current/power), integral measurement function, measurement and analysis of each harmonic (measurement at 50/60Hz meets the requirements of IEC61000 - 4 - 7), external sensor input terminals, and various communication interfaces to assist users in achieving clear, convenient and accurate power measurement.


2. Specification

Input indicators

Item

Voltage

Current

Input type

Floating input via resistor divider

Direct input or sensor input

Input impedance

Approx. 2MΩ

Direct input::

Approx. 500mΩ (200mA and below range)

Approx. 50mΩ (0.5A and above range)

Sensor input: about 100KΩ

Measurement range (RMS)

15V, 30V, 60V, 150V, 300V, 600V

Direct input: 5mA, 10mA, 20mA, 50mA, 100mA, 200mA, 0.5A, 1A, 2A, 5A, 10A, 20A

Sensor input:

50mV, 100mV, 200mV, 500mV, 1V, 2V, 5V, 10V

Maximum continuous input

1.5kV Peak or 1kV RMS, whichever is smaller

30A Peak or 20A RMS, whichever is smaller (200mA and below)

100A Peak or 30A RMS, whichever is smaller (0.5A and above)

Voltage and current accuracy

Item

Specification

DC

±(0.1% reading + 0.2% range)

0.5Hz ≤ f < 45Hz

±(0.1% reading + 0.2% range)

45Hz ≤ f ≤ 66Hz

±(0.1% reading + 0.05% range)

66Hz < f ≤ 1kHz

±(0.1% reading + 0.2% range)

1kHz < f ≤ 10kHz

±[(0.07×f)% reading + 0.3% range]

Temperature coefficient

5 to 18°C or 28 to 40°C: Add ±0.03% of reading.

When the power filter is on

<45Hz: add 0.5% of the reading;

45~66Hz: add 0.2% of the count

Crest Factor Impact

The range error when the crest factor is 6 is twice the range error when the crest factor is 3.

Effect of temperature change after zero calibration or range change

Add 0.02%/°C of range to DC voltage accuracy.

Add the following values ​​to DC current accuracy:

200mA and below range: 5uA/°C;

0.5A and above range: 500uA/°C.

External sensor input: 1mV/°C.

Active power measurement accuracy

Item

Specification

Measurement conditions

Temperature: 23±5℃

Humidity: 30~75%RH (no condensation)

After 30 minutes of preheating

Input waveform: stable DC or sine wave

Common mode voltage: 0V

Crest factor: 3

Power filter: OFF

Frequency filter: On to measure ≤200Hz voltage or current

Zero calibration after measuring range change

DC

±(0.1% reading + 0.2% range)

0.5Hz ≤ f < 45Hz

±(0.3% reading + 0.2% range)

45Hz ≤ f ≤ 66Hz

±(0.1% reading + 0.05% range)

66Hz < f ≤ 1kHz

±(0.2% reading + 0.2% range)

1kHz < f ≤ 10kHz

±(0.1% reading + 0.3% range) ±[0.067×(f-1)% reading]

10kHz < f ≤ 100kHz

±(0.5% reading + 0.5% range) ±[0.09×(f-10)% reading]

Temperature coefficient

5~18℃ or 28~40℃: add ±0.03% of reading.

When the power filter is on

<45Hz: add 1% of reading;

45~66Hz: add 0.3% of count.

Crest Factor Impact

The range error when the peak factor is 6 is twice the range error when the peak factor is 3.


Quality 0.2 Grade Accuracy Digital Power Meter with 0.5Hz to 1000KHz Bandwidth and 5" IPS LCD Display for sale