| Test voltage range: | 0-600V |
| Test current range: | 5mA-20A |
| Power factor: | -1.000~1.000 |
| Power freqency: | 0.5Hz~ 100KHz |
| Accuracy: | ±0.2% |
| Input: | AC100V ~ 240V, 50Hz/60Hz |
| Company Info. |
| Pego Electronics (Yi Chun) Company Limited |
| Verified Supplier |
| View Contact Details |
| Product List |
This is a multifunctional digital power meter for measuring the power of single - phase (1P/2W) AC and DC power supplies. The test frequency range of this product can reach DC 0.5Hz - 100kHz. It uses a 5" IPS LCD display screen, has a 5 - digit measurement display, enables simultaneous measurement of multiple parameters, and possesses high - precision measurement capability. At the same time, it has functions such as waveform display (voltage/current/power), integral measurement function, measurement and analysis of each harmonic (measurement at 50/60Hz meets the requirements of IEC61000 - 4 - 7), external sensor input terminals, and various communication interfaces to assist users in achieving clear, convenient and accurate power measurement.
Input indicators | |||
Item | Voltage | Current | |
Input type | Floating input via resistor divider | Direct input or sensor input | |
Input impedance | Approx. 2MΩ | Direct input:: Approx. 500mΩ (200mA and below range) Approx. 50mΩ (0.5A and above range) Sensor input: about 100KΩ | |
Measurement range (RMS) | 15V, 30V, 60V, 150V, 300V, 600V | Direct input: 5mA, 10mA, 20mA, 50mA, 100mA, 200mA, 0.5A, 1A, 2A, 5A, 10A, 20A Sensor input: 50mV, 100mV, 200mV, 500mV, 1V, 2V, 5V, 10V | |
Maximum continuous input | 1.5kV Peak or 1kV RMS, whichever is smaller | 30A Peak or 20A RMS, whichever is smaller (200mA and below) 100A Peak or 30A RMS, whichever is smaller (0.5A and above) | |
Voltage and current accuracy | |||
Item | Specification | ||
DC | ±(0.1% reading + 0.2% range) | ||
0.5Hz ≤ f < 45Hz | ±(0.1% reading + 0.2% range) | ||
45Hz ≤ f ≤ 66Hz | ±(0.1% reading + 0.05% range) | ||
66Hz < f ≤ 1kHz | ±(0.1% reading + 0.2% range) | ||
1kHz < f ≤ 10kHz | ±[(0.07×f)% reading + 0.3% range] | ||
Temperature coefficient | 5 to 18°C or 28 to 40°C: Add ±0.03% of reading. | ||
When the power filter is on | <45Hz: add 0.5% of the reading; 45~66Hz: add 0.2% of the count | ||
Crest Factor Impact | The range error when the crest factor is 6 is twice the range error when the crest factor is 3. | ||
Effect of temperature change after zero calibration or range change | Add 0.02%/°C of range to DC voltage accuracy. Add the following values to DC current accuracy: 200mA and below range: 5uA/°C; 0.5A and above range: 500uA/°C. External sensor input: 1mV/°C. | ||
Active power measurement accuracy | |||
Item | Specification | ||
Measurement conditions | Temperature: 23±5℃ Humidity: 30~75%RH (no condensation) After 30 minutes of preheating Input waveform: stable DC or sine wave Common mode voltage: 0V Crest factor: 3 Power filter: OFF Frequency filter: On to measure ≤200Hz voltage or current Zero calibration after measuring range change | ||
DC | ±(0.1% reading + 0.2% range) | ||
0.5Hz ≤ f < 45Hz | ±(0.3% reading + 0.2% range) | ||
45Hz ≤ f ≤ 66Hz | ±(0.1% reading + 0.05% range) | ||
66Hz < f ≤ 1kHz | ±(0.2% reading + 0.2% range) | ||
1kHz < f ≤ 10kHz | ±(0.1% reading + 0.3% range) ±[0.067×(f-1)% reading] | ||
10kHz < f ≤ 100kHz | ±(0.5% reading + 0.5% range) ±[0.09×(f-10)% reading] | ||
Temperature coefficient | 5~18℃ or 28~40℃: add ±0.03% of reading. | ||
When the power filter is on | <45Hz: add 1% of reading; 45~66Hz: add 0.3% of count. | ||
Crest Factor Impact | The range error when the peak factor is 6 is twice the range error when the peak factor is 3. | ||
|