1 T Clamping Force Package Testing Equipment For Clamp Compression
Testing
Clamp Compression Testing Method of Large Products
1.Before placing the packaged product between platens, verify that
the clamp force using the clamp indicator. The indicator should be
placed between the axes of the platen articulation points
approximately 1/2 way up the platens.
2.Each time the product is clamped, the force should be applied for
a minimum of 15 seconds and not to exceed 1 minute.
3. This Equipment applies the clamp force on the sample with the
platens resting on the floor and the front edge of the platens
flush with the front of the package. If the package is too large
for the clamps to be flush to front edge (i.e., large refrigerator,
tractor etc.), clamp as close to the edge as possible.
4. Clamp the product a total of 10 times in the flush orientation.
5. Apply the clamp force on the packaged product with the platens
in a 6×6 inch(15.2x15.2cm) offset position. Both the horizontal and
vertical offset dimensions are measured at the front bottom corner
of the platen. If the package is too large for the clamp to be
positioned 6-inches from the front edge (i.e., large refrigerator,
tractor etc.), clamp as close to this position as possible.
6. Clamp the product a total of 10 times with the clamp in the 6 x6
inch offset position.
7. Repeat step 5 except with a 2 x6 inch offset clamp position. The
2 x6 inch offset is similar to the 6 x6 inch offset except the
platens are oriented such that they are 2-inches from the floor and
6-inches back from the package’s front edge. If the package is too
large for the clamps to be positioned 2-inches from the front edge
(i.e., large refrigerator, tractor etc.), clamp as close to this
position as possible.
8. Repeat flush and offset clamping on all other sides of the
product that are indicated in the handling graphics as acceptable
for clamp handling.
According to verdict standards, if there is one item failed the
test, then put forward the “Test Failure Handling Sheet"
Techinical Parameters For Large Product
Clamping force | 1T |
color | optional |
Resolution | 1/100,000 |
Test Space(L x W x H) | 100x 100 x 100cm |
Test Speed | 10±3mm/min |
Weight | around 300kg |
Power | 1#, 220V/50HZ |
Safety protection
Overload protection, overvoltage protection & limited position
protection device
Clamp Compression Testing Method of Small Products
Before clamp testing, verify that the clamp for using the clamp
force indicator. The indicator should be placed between the axes of
the platen articulation points approximately 1/2 way up the
platens.
During clamp compression testing of small products, 4 samples will
be utilized as outlined below.
1. When oriented for clamp testing (based on the handling graphics)
the sides perpendicular to the platens of a single sample ≤ 24”
(61cm), then the 4 sample should be placed in a”side by
side”oritentation (with 2 samples on the bottom and 2 on the top)
2. If, when oriented for clamp testing the sides perpendicular to
the platens of a single sample are >24” (61cm),, then the 4
samples should be placed in a top-bottom orientation. If, when
placed 4-high, any of the samples are completely above the top of
the platens, that sample can be removed from clamping in this
orientation only
3 Each time the samples are clamped, the force should be applied
for a minimum of 15 seconds and not to exceed 1 minute.
4 .Apply the clamp force on the samples with the platens resting on
the floor and the samples flush with the front edge of the platens.
If the samples are too large for the clamps to be flush to front
edge, clamp as close to the edge as possible.
5.Clamp the product a total of 10times with the clamps in the flush
orientation.
6.ASTM D6055 PLC Control Package Compression Testing MachineApply
the clamp force on the packaged product with the platens in a 2×2
inch offset position. Both the horizontal and vertical offset
dimensions are measured at the front bottom corner of the platen.
If the package is too large for the clamps to be positioned
2-inches from the front edge, clamp as close to this position as
possible.
7. Clamp the product a total of 10 times with the clamps in the
offset position.
8. Repeat the flush and 2x2 inch offset camping on all other sides
of the product that are identified in the handling graphics as
acceptable for clamp handling. Please note, depending on the box
geometry, you may use both the side-by-side and top-bottom
orientation during clamp testing.
Techinical Parameters for Small Product
Clamping force: | 50-3000kg |
Size of the clamping board: | 1200 by 1200mm |
Maximum clamping space: | 1200 by 1200 by 1200mm |
Minimum clamping space: | 400 by 1200 by 1200mm |
Clamping speed: | 5-50mm/min |
Up-down space: | 100-600mm, adjustable, can be customized |
Dimension: 3 | 810 by 1900 by 2100 |
Weight: | 800kg |
Power: | 380v/ 50Hz |
Control system: | PLC programmed control |
Photo Refernce