Optical Geometry: | 8°/d |
Measuring Aperture: | Φ8mm & Φ4mm |
Repeatibility: | ΔE*≤0.06 |
Inter-instrument Agreement: | ΔE*≤0.4 |
Light Source: | D65 D50 A |
Color Difference Formula: | ΔE*ab ΔL*a*b ΔE*C*hΔECIE94 |
NH310 plastic colorimeter color test meter to replace CR10 plus chroma meter
Information:
NH310 colorimeter features the function of automatic white and black calibration when switched on and also a simple interface, making it's very convenient to measure. Elegant appearance combines perfectly with the ergonomic design, which makes it a model of portable handheld colorimeter.
NH310 high-quality portable colorimeter has adopted multi-channel
color sensors of international brands, more stable IC platform as
well as efficient and accurate algorithms to provide users with
accurate and fast color management and application. NH310 is also
designed with ergonomics and humanized operation and it has applied
for a number of patents. NH310 is a multifunctional colorimeter
with high quality and competitive price. 3nh insists on independent
research whose technology innovation is unique in color management
field. NH310 is the most convenient colorimeter for users.
NH310 colorimeter is standardly configured with 2 kinds of
measuring apertures, 8mm and 4mm, and one extended 8mm aperture
optionaly, multiple light source modes, multiple color space
systems, multiple chromaticity indexes conforming to different
standards, all of which make NH310 can excellently fulfill all
kinds of requirements for color measurements in different
industries.
NH310 colorimeter has many functions which can measure color
fastness, whiteness (Hunter and ISO R457), Yellowness (YI), etc.
However, we can also customize the following light sources for
customers.
Potents:
No.1 Camera locating and illumination location (NH310 has new functions of double locating.)
No. 2 Built-in white plate; Automatic calibration at startup (for NH310)
No. 3 Extended aperture (optional), available for measuring concave surface
Application:
NH310 colorimeter has many functions which can measure color fastness, whiteness (Hunter and ISO R457), Yellowness (YI), etc. However, we can also customize the following light sources for customers. It's used to compare color difference in plastic, electronic, painting, coating, ink, texile, garment, printing, dyeing, food, medical, cosmetic industries and institutes, schools and laboratoris.
Specification:
Model | NH310 Colorimeter |
Illuminating/Viewing Geometry | 8/d |
Measuring Aperture | Φ8mm/Φ4mm |
Detector | Silicon photoelectric diode |
Color Space | CIEL*a*b*C*h* CIEL*a*b* CIEXYZ CIERGB CIEL*u*v* CIEL*C*h Yellowness & Whiteness Color Fastness |
Color Difference Formula | ΔE*ab ΔL*a*b ΔE*C*hΔECIE94 |
Light Source | D65 D50 A |
Light Source Device | LED blue light excitation |
Errors Between Each Equipment | ≤0.40ΔE*ab |
Storage | 100pcs standards 20000pcs samples |
Repeatability | Standard deviation within ΔE*ab 0.06 Average of 30 measurements of standard white plate |
Weight | 500g |
Dimension | 205×70×100 mm |
Power source | Rechargeable lithium-ion battery 3.7V@3200mAh |
Lamp Life | 5 years, more than 1.6 million measurements |
Charging Time | 2 hours (first time 8 hours--100% electricity) |
Measurement Times Before Recharging | More than 3000 times |
Operating Temperature/Humidity Range | -10~40℃, relative humidity 0~85% with no condensation |
Data Interface | USB |
Extended Aperture (optional) | Φ8mm extended aperture, available for measuring concave surface |
Printer (optional) | Miniature thermal printer |
Images:
Company:
Shenzhen 3nh Technology Co., Ltd. is a high-tech enterprise. We research, develop, produce and market photoelectric detection products in photoelectric detection technology field and color management field.After years of intensice research, 3nh has launched YS series spectrophotometer, NS series spectrophotometer and NH, NR series colorimeter, ISO12233 resolution test chart, optical image test solution and specific standard illuminant which are widely used in plastic, electronic, paint, ink, textile, garment, printing and dyeing, food, medical, cosmetic, optical image test industries and the field of scientific research, school and laboratory. Our products are exported around the world. We can provide customization service which has been well received by customers.
FAQ:
1. When I received NH310/NH300 colorimeter and perform measurement,
why the measured data is abnormal?
After receiving NH310/NH300, you have to perform white and black
calibration manually when first starting.
2. In which condition, manual white and black calibration and auto
calibration are required for NH310?
a. It’s needed to perform manual calibration for NH310 when first
starting.
b. In the subsequent starting, NH310 will perform auto calibration
at startup. No need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week
or when NH310 measured data is not accurate.
3. In which condition, manual white and black calibration for NH300
is required?
a. It’s needed to perform manual calibration for NH300 when first
starting.
b. In the subsequent starting, no need to perform manual
calibration.
c. Suggestion: it’s best to perform manual calibration once a week
or when NH300 measured data is not accurate.
4. How to replace NH310 measuring aperture?
There are three measuring apertures for NH310: Φ8mm (standard
accessory), Φ4mm (standard accessory), extended Φ8mm (optional
accessory)
a. Turning on
b. Removing measuring aperture, install the needed measuring
aperture.
c. Select “Settings-Aperture Setting” in main menu to select
corresponding measuring aperture.
d. After selecting aperture, the instrument will display “White and
Black Calibration” interface. White and black calibration must be
performed.
e. Replace completed.
5. CQCS3 (Color Quality Control System) Installation
a. Before installation, please Copy CQCS3 folder to your computer
and don’t remove any files in CQCS3 folder.
b. Double-click the setup.exe to install CQCS3 software.
c. Then double-click Install.bat under the CQCS3USB_Driver file to
install the driver.
d. Detailed installation information please read the "Installing
Software" under CQCS3 User manual.doc.
Warranty:
NH310 color reader colorimeter for liquid powder coffee colour
check with accessory is under warranty for 12 months from the
purchase date. Customers must provide warranty card and valid proof
of purchase.
About Us
Customer Services
Sell On Us
Friendly Links: www.everychina.com
Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们